The pulmonary capillary wedge pressure is 10 mmHg. The Indigo Separator is advanced and retracted through the corresponding size Indigo catheter at the proximal margin of the primary occlusion to facilitate clearing of the thrombus from the catheter tip. The Indigo System CAT3, CAT5, CAT6, CAT8, CATD, and CAT7D are engineered to be robust, trackable, atraumatic, and well suited for the peripheral anatomy. The initial angiogram confirmed an occlusion with extensive thrombus burden of a dominant left circumflex artery and TIMI 0 flow (Figure 1). If such use is necessary, this equipment and the other equipment should be observed to verify that they are operating normally. INDIGO Aspiration System with LIGHTNING Aspiration Tubing Indication for Use Jawairia Sahar K. Mirza, MBBS
The Indigo Separator 4 is not intended for use as a guidewire. The Indigo System is intended for the removal of fresh, soft emboli and thrombi from vessels of the peripheral and venous systems, and certain central circulatory systems conditions such as pulmonary emboli, using continuous aspiration. Available in a selection of sizes, the CAT family can provide access to distal peripheral vessels of the upper and lower extremities, including below the knee. Alameda, CA 94502. Possible complications include, but are not limited to, the following: Pela bainha, foi introduzido o dispositivo de aspirao Penumbra Indigo System CAT8 XTORQ (Penumbra Inc., Alameda, Califrnia, Estados Unidos) em trombo segmentar, lobar ou arterial pulmonar principal, sendo realizada aspirao contnua (Figuras 2 e 3). This is potentially more effective than diminished syringe-based aspiration. Return all damaged devices and packaging to the manufacturer/distributor. This case illustrates the vast improvement in aspiration technology with an easy-to-deliver, trackable catheter that maintains sustained aspiration for the duration of the procedure. INDIGO Aspiration Tubing: If the device is forcefully retracted at extreme angles during removal from the packaging, damage such as this may occur. Figure 1. With a maximised inner diameter of 0.08 (2.1 mm) and a 7 French (2.3 mm) outer diameter, CAT7 is 93% the size of CAT8, now with a lower profile. Aspiration or disruption of thrombus with traditional diminished syringe-based aspiration or other mechanical devices is difficult, often incomplete, and has been associated with high complication rates.1 Use of medical therapy, such as powerful anticoagulants and thrombolytics (ie, tissue plasminogen activator), may carry a high risk of bleeding.2 The Indigo System was designed to provide sustained aspiration with Penumbra ENGINE to effectively remove thrombus, while reducing the risk of bleeding complications.3 The Indigo System utilizes atraumatic catheters varying in diameters from 3.4 to 8 F and lengths ranging from 50 to 150 cm. Made of laser-cut hypotube technology, CAT7 and CAT12 are designed to increase trackability and torqueability. 5, 19. Use prior to the Use By date. The newest indication for the Indigo System is the treatment of pulmonary embolism; this indication comes on the heels of the promising results of the EXTRACT-PE trial. Mechanical clot engagement with proprietary Separator technology, Tip directionality for circumferential aspiration, The Indigo System is an integrated system for use only with other components of the Indigo System including the CAT family of catheters, Separators, Dynamic Aspiration Tubing, Lightning, Penumbra ENGINE, and Penumbra ENGINE Canister, Lightning Computer-Aided Aspiration comes packaged with CAT7 or CAT12, Live feedback during the procedure with integrated clot catcher, Penumbra ENGINE is capable of delivering and maintaining nearly pure vacuum (-29 inHg or 98.2 kPa) with the disposable Penumbra ENGINE Canister. Flow through left circumflex artery post-CAT RX. The advantages of CAT RX with Penumbra ENGINE include the potential to remove the thrombus intact and reduce the potential of systemic embolization while also increasing the visualization of the underlying stenosis and distal vessel. Return all damaged devices and packaging to the manufacturer/distributor. We decided to start with mechanical aspiration using CAT RX and Penumbra ENGINE to extract the thrombus. If repositioning of the INDIGO Aspiration Catheter is necessary during the revascularization procedure, such repositioning should be performed over an appropriate guidewire using standard catheter and guidewire techniques. Copyright 2022 Penumbra, Inc. All rights reserved. 0, 26. We started with laser atherectomy followed by percutaneous transluminal angioplasty of the tibial peroneal trunk, peroneal artery, and posterior tibial artery. The Indigo Aspiration System is comprised of several devices: The Indigo System is used as a first-line approach or rescue therapy for arterial and venous thrombotic events. CHEETAH will focus on patients presenting with high-grade thrombus burden who receive frontline treatment with CAT RX. The cat8 was kinked approximately 69. . Enter your email address and we will contact you. Pinterest; CAT8 KIT Indigo System Aspiration Catheter 8 and Aspiration Tubing - XTORQ - 8Fr x 115cm Penumbra System) Model #: CAT8XTORQ115KIT OEM: Penumbra System Expiration Date: 2022 Size : 8Fr x 115cm . Results of EXTRACT-PE Trial presented at Vascular InterVentional Advances (VIVA) Annual Meeting Penumbra, Inc. (NYSE: PEN), a global healthcare company focused on innovative therapies, today announced that the EXTRACT-PE trial successfully met the primary endpoints, demonstrating the safety and efficacy of the Indigo Aspiration System for aspiration mechanical thrombectomy in patients with . 0, and 37. Conclusions: evaluation of the cat8 revealed that the device was fractured. Contraindications Do not use in the presence of a flammable anesthetic mixture with air or nitrous oxide. The catheters (CAT3, CAT RX*, CAT5, CAT6, CAT8, CATD) vary in diameters from 3.4 to 8 F and lengths of 50 to 150 cm to . Warnings Not for use in the coronaries or the neurovasculature. The Penumbra IndigoSystem Separatoris intended for use with our Indigo Systems CATfamily of catheters to enable the removal of a wide range of thrombus. Jolly SS, Cairns JA, Lavi S, et al. Do not use in an oxygen rich environment. Figure 3. Do not reuse. The patient had a robust recovery and was discharged to her rehab facility on anticoagulation. Learn more about Lightning. Available in a selection of sizes, the CAT family can provide access to distal peripheral vessels of the upper and lower . The sustained aspiration power provided by the Penumbra ENGINE allowed rapid TIMI 3 flow restoration and removal of the distal emboli. Also find Catheter price list from verified suppliers with contact number | ID: 23694008673 Units in stock: 1. Do not use open or damaged packages. Her heart rate was 110 beats per minute, elevated troponin levels at 4.5 ng/mL, and elevated brain natriuretic peptide at 1,164 pg/mL. Do not advance, retract or use any component of the INDIGO System against resistance without careful assessment of the cause using fluoroscopy. Chris Metzger, MD
Indigo Aspiration Catheters (CAT) are the foundation of Penumbra's Indigo System. Ultrasound-guided access was obtained through the right femoral vein. The removal of fibrous, adherent or calcified material (e.g. Penumbra System ACE 68 KIT Reperfusion Catheter & Penumbra Hi-Flow Aspiration Tubing - 6Fr x .068" x 132cm: 6Fr x .068" x 132cm $600.00. allergic reaction and anaphylaxis from contrast media; acute occlusion; air embolism; arteriovenous fistula; death; device malfunction; distal embolization; emboli; false aneurysm formation; hematoma or hemorrhage at access site; inability to completely remove thrombus; infection; hemorrhage; ischemia; kidney damage from contrast media; neurological deficits including stroke; vessel spasm, thrombosis, dissection, or perforation; intimal disruption; myocardial infarction; emergent surgery; fibrillation; hypotension; respiratory failure; peripheral thromboembolic events. The CAT family of catheters is the foundation of Penumbras Indigo System. Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 12 inches (30 cm) to any part of the PENUMBRA ENGINE. Precautions The safety and effectiveness of this device for use in the treatment of ST-Elevation Myocardial Infarction (STEMI) has not been established. When performing aspiration, ensure that the INDIGO Aspiration Tubing is open for only the minimum time needed to remove the thrombus. Penumbra Aspiration Pump: The Penumbra Aspiration Pump is indicated as a vacuum source for Penumbra Aspiration Systems. With automatic valve control, Lightning can help the physician focus on optimizing thrombus removal procedures. No modification of this equipment is allowed. Copyright 2023 Penumbra, Inc. All rights reserved. gtag('js', new Date()); INDIGO Aspiration Catheters and Separators: As part of the INDIGO Aspiration System, the INDIGO Aspiration Catheters and Separators are indicated for the removal of fresh, soft emboli and thrombi from vessels of the peripheral arterial and venous systems, and for the treatment of pulmonary embolism. 3. Medical Director, Aortic Disease and Ischemic Limb Disease
IN-DATE. Saxon RR, Benenati JF, Teigen C, et al. She was in a rehab facility prior to this new event recovering from her CVA. window.dataLayer = window.dataLayer || []; Figure 2. The Penumbra CAT RX catheter was used in a total of 34 patients, with 71% STEMI, 23% NSTEMI, 3% UA, and 3% new onset heart failure. CAT12 features a large 0.13 (3.33 mm) lumen and angled tip for additional circumferential sweep. The INDIGO Aspiration System is intended to serve as a conduit to assist in thrombus removal and restoration of blood flow in the peripheral vasculature and for the treatment of pulmonary embolism. 2017;377:2240-2252. Penumbra Aspiration Pump: Penumbra CAT8TORQ85 CAT8 Indigo Aspiration Catheter 8, TORQ tip, 85cm , 8Fr., Peripheral Thrombectomy Mechanical one each . Equipment is not safe for MR use. Complications from the use of this device in this manner could lead to death, permanent impairment, and/or the need for emergency medical intervention. INDIGO Aspiration Tubing: As part of the INDIGO Aspiration System, the INDIGO Sterile Aspiration Tubing is indicated to connect the INDIGO Aspiration Catheters to the Penumbra Aspiration Pump. We directly stented with a 3.5- X 38-mm Synergy DES and postdilated with a 4- X 20-mm noncompliant balloon. Available in a selection of sizes, the CAT family can provide access to distal peripheral . Power aspiration with CAT RX and Penumbra ENGINE was started after wiring the dominant left circumflex artery. Do not use the INDIGO Aspiration System with a pump other than the Penumbra Aspiration Pump. Indigo Aspiration System Intended Use Indigo System Intended Use SVG occlusions can be challenging to resolve using traditional treatment modalities. No modification of this equipment is allowed. Hemoglobin and hematocrit levels should be monitored in patients with >700 mL blood loss from the clot aspiration procedure. Lightning 7 expands Penumbra's offering of the Indigo Aspiration System with Intelligent Aspiration for mechanical thrombectomy and is designed for single session arterial thrombus removal. Indigo System | Computer-Aided Mechanical Aspiration. As part of the Indigo Aspiration System, the Indigo CAT RX Aspiration Catheters and Indigo Separator 4 (Penumbra, Inc.) are indicated for the removal of fresh soft emboli and thrombi from vessels in the coronary and peripheral vasculature. Disclosures: Consultant to Penumbra, Inc. An 83-year-old woman transferred from an outside hospital presented with acute shortness of breath, was hypotensive, and was intubated. Remove and service the PENUMBRA ENGINE if liquids or solids have been drawn into the PENUMBRA ENGINE. function gtag(){dataLayer.push(arguments);} Penumbra introduced the Indigo System CAT RX in 2017 for the removal of fresh, soft emboli and thrombi from the coronary and peripheral vasculature. Initial angiogram showing high thrombus burden in the RCA. INDIGO CAT RX Aspiration Catheters and INDIGO SEPARATOR 4 Indication for Use As part of the INDIGO Aspiration System, the INDIGO CAT RX Aspiration Catheters and INDIGO SEPARATOR 4 are indicated for the removal of fresh, soft emboli and thrombi from vessels in the coronary and peripheral vasculature. Copyright 2023 Penumbra, Inc. All rights reserved. Penumbra has issued an urgent recall of all configurations of the Penumbra JET 7 Reperfusion Catheter with Xtra Flex Technology (JET 7 Xtra Flex) based on the risk of unexpected death or serious . Penumbra CAT8XTORQ115 CAT8 Indigo System Aspiration Catheter 8F Item Past Expiration. Contraindications There are no contraindications. Warnings/Precautions The CAT family of catheters is the foundation of Penumbra's Indigo system. Cedars Sinai Medical Center
Brian Kolski, MD
Use of LIGHTNING Aspiration Tubing adjacent to other equipment should be avoided because it could result in improper operation. Smidt Heart institute
To prevent fire or shock hazard, use a replacement power cord of equal rating. 510 (k) Number. Do not use in an oxygen rich environment. Return all damaged devices and packaging to the manufacturer/distributor. As part of the INDIGO Aspiration System, the INDIGO Sterile Aspiration Tubing is indicated to connect the INDIGO Aspiration Catheters to the Penumbra Aspiration Pump. Catheters; CAT8 KIT Indigo System Aspiration Catheter 8 and Aspiration Tubing - XTORQ - 8Fr x 115cm . Waqas R. Qureshi, MD, MS
2019;140:e774-e801. Presented at: American College of Cardiologys 68th Annual Scientific Session; March 1618, 2019; New Orleans, LA. The large aspiration lumen and highly trackable, low-profile design coupled with the power of the Penumbra ENGINE resulted in the successful removal of the emboli in one pass. When performing aspiration, ensure that the Indigo Aspiration Tubing valve is open for only the minimum time needed to remove thrombus. Potential Adverse Events Possible complications include, but are not limited to, the following: allergic reaction and anaphylaxis from contrast media; acute occlusion; air embolism; arteriovenous fistula; death; device malfunction; distal embolization; emboli; false aneurysm formation; hematoma or hemorrhage at access site; inability to completely remove thrombus; infection; hemorrhage; ischemia; kidney damage from contrast media; neurological deficits including stroke; vessel spasm, thrombosis, dissection, or perforation; intimal disruption; myocardial infarction; emergent surgery; fibrillation; hypotension; respiratory failure; peripheral thromboembolic events.